Search results for "Legionella pneumophila"

showing 10 items of 33 documents

Genomic investigation of a legionellosis outbreak in a persistently colonized hotel

2016

Objectives: A long-lasting legionellosis outbreak was reported between November 2011 and July 2012 in a hotel in Calpe (Spain) affecting 44 patients including six deaths. Intensive epidemiological and microbiological investigations were performed in order to detect the reservoirs. Methods: Clinical and environmental samples were tested for the presence and genetic characterization of Legionella pneumophila. Six of the isolates were subjected to whole-genome sequencing. Results: Sequencing of 14 clinical and 260 environmental samples revealed sequence type (ST) 23 as the main responsible strain for the infections. This ST was found in the spa pool, from where it spread to other hotel public …

0301 basic medicineMicrobiology (medical)medicine.medical_specialtyMixed infectionsSequencing datacomplete genomelcsh:QR1-502MicrobiologiaBiologyLegionella pneumophilaMicrobiologylcsh:MicrobiologyMicrobiology03 medical and health sciencesEpidemiologymedicineColonizationTypingOriginal ResearchDirect sequencingtypingOutbreakLegionnaire's disease (LD)biology.organism_classificationmedicine.diseaseSalut públicaoutbreak investigation030104 developmental biologyoutbreaksLegionel·losiLegionnaires' diseaseLegionnaires' Disease
researchProduct

Control and prevention measures for legionellosis in hospitals: A cross-sectional survey in Italy

2018

Abstract Risk assessment, environmental monitoring, and the disinfection of water systems are the key elements in preventing legionellosis risk. The Italian Study Group of Hospital Hygiene of the Italian Society of Hygiene, Preventive Medicine, and Public Health and the Italian Multidisciplinary Society for the Prevention of Health Care-Associated Infections carried out a national cross-sectional survey to investigate the measures taken to prevent and control legionellosis in Italian hospitals. A multiple-choice questionnaire was developed, comprising 71 questions regarding hospital location, general characteristics, clinical and environmental surveillance, and control and preventive measur…

0301 basic medicinemedicine.medical_specialtyCross-sectional studyLegionellamedia_common.quotation_subject030106 microbiologyControl measuresBiochemistryControl measures; Hospital; Legionellosis; National survey; Prevention; Biochemistry; 2300Legionella pneumophila03 medical and health sciencesHospital0302 clinical medicineControl measures; Hospital; Legionellosis; National survey; Prevention; Cross Infection; Cross-Sectional Studies; Disinfection; Humans; Infection Control; Italy; Legionella pneumophila; Legionellosis; Surveys and Questionnaires; Water Microbiology; Water SupplyHygieneWater SupplyLegionellosiSurveys and Questionnairesmedicinecontrol measures; hospital; legionellosis; national survey; preventionControl measures Hospital Legionellosis National survey Prevention Biochemistry 2300Humans030212 general & internal medicineSeroconversionGeneral Environmental SciencePreventive healthcaremedia_commonResponse rate (survey)National surveyCross InfectionInfection ControlLegionellosisbiology2300business.industryPublic healthPreventionControl measurebiology.organism_classificationDisinfectionCross-Sectional StudiesItalyEmergency medicinebusinessRisk assessmentWater Microbiology
researchProduct

Clinical Epidemiological Survey of Legionella pneumophila Infections in Italy

1986

A clinical epidemiological survey of Legionella pneumophila infections occurring in Italy between 1 December 1985 and 31 May 1986 was carried out to evaluate the incidence of sporadic, epidemic and nosocomial L. pneumophila pneumonia. A total of 355 cases of pneumonia were studied of which 11.5% were due to Gram positive bacteria, 11% were due to Gram negative bacteria, 7.9% were due to Mycoplasma pneumoniae, 4.5% were due to L. pneumophila and 8.5% were due to sundry aetiological agents. The remainder (45.6%) could not be diagnosed accurately. In addition, the anti L. pneumophila antibody titres were assessed. The results are discussed in terms of the occurrence of the disease in Italy an…

AdultMalemedicine.medical_specialtyMycoplasma pneumoniaeGram-negative bacteriaAdolescentGram-positive bacteriamedicine.disease_causeBiochemistryLegionella pneumophilaMicrobiologyEpidemiologymedicineHumansChildAgedAged 80 and overbiologybusiness.industryIncidence (epidemiology)Biochemistry (medical)InfantCell BiologyGeneral MedicineMiddle Agedmedicine.diseasebiology.organism_classificationrespiratory tract diseasesPneumoniaItalyChild PreschoolEtiologyFemaleLegionnaires' DiseasebusinessJournal of International Medical Research
researchProduct

Can technical, functional and structural characteristics of dental units predict Legionella pneumophila and Pseudomonas aeruginosa contamination?

2011

Legionella pneumophila and Pseudomonas aeruginosa are common colonizers of water environments, particularly dental unit waterlines. The aim of this study was to assess whether the technical, functional and structural characteristics of dental units can influence the presence and the levels of opportunistic pathogens. Overall, 42 water samples were collected from dental units in a teaching hospital in Palermo, Italy, including 21 samples from the 21 taps supplied by the municipal water distribution system and 21 samples from oral rinsing cups at 21 dental units. L. pneumophila was present in 16 out of 21 water samples (76.2%) from dental units, and the median concentration was higher in samp…

Air MicrobiologyColony Count MicrobialDental Facilitiesmedicine.disease_causeSettore MED/42 - Igiene Generale E ApplicataLegionella pneumophilaDental EquipmentRisk AssessmentMicrobiologyTeaching hospitalLegionella pneumophilaDistribution systemmedicineDental FacilitiesHumansopportunistics pathogens dental unit waterlines risk assessment.General DentistryRespiratory Tract InfectionsHealth Facility SizebiologyPseudomonas aeruginosabusiness.industryContaminationbiology.organism_classificationVentilationOccupational Diseasesstomatognathic diseasesFacility Design and ConstructionPseudomonas aeruginosaEquipment ContaminationEquipment ContaminationWater qualitybusinessWater MicrobiologyJournal of oral science
researchProduct

Geographical and temporal structures of Legionella pneumophila sequence types in comunitat valenciana (Spain), 1998 to 2013

2015

ABSTRACT Legionella pneumophila is an accidental human pathogen associated with aerosol formation in water-related sources. High recombination rates make Legionella populations genetically diverse, and nearly 2,000 different sequence types (STs) have been described to date for this environmental pathogen. The spatial distribution of STs is extremely heterogeneous, with some variants being present worldwide and others being detected at only a local scale. Similarly, some STs have been associated with disease outbreaks, such as ST578 or ST23. Spain is among the European countries with the highest incidences of reported legionellosis cases, and specifically, Comunitat Valenciana (CV) is the se…

DNA BacterialBIOFILMS[SDV.BIO]Life Sciences [q-bio]/BiotechnologyGenotypeLegionellaOUTBREAKSequence HomologyZoologyRECOMBINATIONHuman pathogenLEGIONNAIRES-DISEASESOFTWAREBiologySpatial distributionApplied Microbiology and BiotechnologyLegionella pneumophilaLegionella pneumophilaMicrobiology03 medical and health sciencesSpatio-Temporal AnalysisEnvironmental MicrobiologyCluster AnalysisHumansTypingPOPULATION-STRUCTUREPhylogeny030304 developmental biology0303 health sciencesEcologyPublic and Environmental Health Microbiology030306 microbiologySTRAINSSCHEMELocal scaleGenetic VariationOutbreakSequence Analysis DNASequence typesbiology.organism_classification3. Good healthMolecular TypingLIFE[SDV.MP]Life Sciences [q-bio]/Microbiology and ParasitologySpainLegionnaires' DiseaseFood ScienceBiotechnology
researchProduct

Genotyping of Legionella pneumophila serogroup 1 strains isolated in Northern Sicily, Italy.

2008

During a three-year period, from April 2002 to May 2005, one hundred-forty-seven samples, taken from technical systems of water distribution at point of use, were repeatedly collected at six different sites in Northern Sicily and assayed for the presence of Legionella pneumophila serogroup 1 and serogroups 2 to 14. At the first samplings, the water distribution systems of all the sites were heavily contaminated, and disinfection treatments by the superheat and flush method were therefore performed. Treatments were always successful against L. pneumophila sg.1, but only in a few cases against all other serogroups. Eighty-six strains of L. pneumophila sg. 1, isolated from 26 of these samples,…

DNA BacterialDisinfectionMolecular EpidemiologySettore MED/07 - Microbiologia E Microbiologia ClinicaGenotypeCluster AnalysisFresh WaterSequence Analysis DNAAmplified Fragment Length Polymorphism AnalysisLegionella pneumophila Surveillance Water distribution system Molecular typing Amplified fragment length polymorphismSicilyBacterial Typing TechniquesLegionella pneumophila
researchProduct

Oligonucleotide-capped mesoporous silica nanoparticles as DNA-responsive dye delivery systems for genomic DNA detection

2015

[EN] New hybrid oligonucleotide-capped mesoporous silica nanoparticles able to detect genomic DNA were designed.

DNA BacterialINGENIERIA DE LA CONSTRUCCIONDesignControlled-releaseSupportsOligonucleotidesNanoparticleNanotechnologyCatalysisLegionella pneumophilachemistry.chemical_compoundQUIMICA ORGANICAhemic and lymphatic diseasesCandida albicansBIOQUIMICA Y BIOLOGIA MOLECULARMaterials ChemistryMycoplasma fermentansColoring AgentsStimuliRhodaminesOligonucleotideChemistryQUIMICA INORGANICAMetals and AlloysGenomicsGeneral ChemistryMesoporous silicaSilicon DioxideControlled releaseDrug-deliverySurfaces Coatings and FilmsElectronic Optical and Magnetic Materialsgenomic DNADrug deliveryCeramics and CompositesNanoparticlesDNAChemical Communications
researchProduct

Population structure and recombination in environmental isolates of Legionella pneumophila

2007

Legionella pneumophila is a water-borne bacteria responsible for most cases of legionellosis, an emerging disease with an increasing incidence in industrialized countries. Although early analysis based on multilocus enzyme electrophoresis (MLEE) described the population structure of this species as clonal, more recent reports have suggested that recombination also contributes to shaping variation across its genome. We report here the results of analysing the nucleotide sequences of 19 loci in 31 environmental samples of L. pneumophila from a small Spanish region (near Alcoi, province of Alicante) where legionellosis has become almost endemic. We analysed the six loci currently incorporated …

DNA BacterialSequence analysisMolecular Sequence DataLocus (genetics)MicrobiologyLegionella pneumophilaGenomeLegionella pneumophilaIntergenic regionBacterial ProteinsWater SupplyGenetic variationEnvironmental MicrobiologyAir ConditioningEcology Evolution Behavior and SystematicsRecombination GeneticGeneticsBase SequencebiologyGenetic VariationSequence Analysis DNAbiology.organism_classificationPathogenicity islandSpainDNA IntergenicRecombinationEnvironmental Microbiology
researchProduct

Genetic Characterization of Legionella pneumophila Isolated from a Common Watershed in Comunidad Valenciana, Spain

2013

Legionella pneumophila infects humans to produce legionellosis and Pontiac fever only from environmental sources. In order to establish control measures and study the sources of outbreaks it is essential to know extent and distribution of strain variants of this bacterium in the environment. Sporadic and outbreak-related cases of legionellosis have been historically frequent in the Comunidad Valenciana region (CV, Spain), with a high prevalence in its Southeastern-most part (BV). Environmental investigations for the detection of Legionella pneumophila are performed in this area routinely. We present a population genetics study of 87 L. pneumophila strains isolated in 13 different localities…

Evolutionary GeneticsBacterial DiseasesPopulation geneticslcsh:MedicineLocus (genetics)Legionella pneumophilaMicrobiologyMicrobial EcologyLegionella pneumophilaIntergenic regionGenetic variationmedicineNatural SelectionGeneticsGram Negativelcsh:ScienceBiologyMicrobial PathogensGeneticsRecombination GeneticGenetic diversityEvolutionary BiologyMultidisciplinaryLegionellosisbiologyEcologyEcologyPontiac feverlcsh:ROutbreakGenetic Variationbiology.organism_classificationmedicine.diseaseBacterial PathogensInfectious DiseasesSpainMicrobial EvolutionGenetic PolymorphismMedicinelcsh:QWater MicrobiologySequence AnalysisPopulation GeneticsResearch ArticlePLoS ONE
researchProduct

Genetic variability in environmental isolates of Legionella pneumophila from Comunidad Valenciana (Spain).

2006

Summary Legionella pneumophila is associated to recurrent outbreaks in several Comunidad Valenciana (Spain) localities, especially in Alcoi, where social and climatic conditions seem to provide an excellent environment for bacterial growth. We have analysed the nucleotide sequences of three loci from 25 environmental isolates from Alcoi and nearby locations sampled over 3 years. The analysis of these isolates has revealed a substan- tial level of genetic variation, with consistent patterns of variability across loci, and comparable to that found in a large, European-wide sampling of clinical isolates. Among the tree loci studied, fliC showed the highest level of nucleotide diversity. The an…

GeneticsRecombination GeneticLinkage disequilibriumGeographyPopulation structureMolecular Sequence DataOutbreakGenetic VariationSequence Analysis DNABiologybiology.organism_classificationMicrobiologyLegionella pneumophilaLinkage DisequilibriumNucleotide diversityLegionella pneumophilaSpainGenetic variationGenetic variabilityLegionnaires' DiseaseEcology Evolution Behavior and SystematicsAllelesEnvironmental MonitoringEnvironmental microbiology
researchProduct